RANGE0=00, LP=0, IRCS=0, EREFS0=0, LOCRE0=0, HGO0=0
MCG Control 2 Register
IRCS | Internal Reference Clock Select 0 (0): Slow internal reference clock selected. 1 (1): Fast internal reference clock selected. |
LP | Low Power Select 0 (0): FLL or PLL is not disabled in bypass modes. 1 (1): FLL or PLL is disabled in bypass modes (lower power) |
EREFS0 | External Reference Select 0 (0): External reference clock requested. 1 (1): Oscillator requested. |
HGO0 | High Gain Oscillator Select 0 (0): Configure crystal oscillator for low-power operation. 1 (1): Configure crystal oscillator for high-gain operation. |
RANGE0 | Frequency Range Select 0 (00): Encoding 0 - Low frequency range selected for the crystal oscillator . 1 (01): Encoding 1 - High frequency range selected for the crystal oscillator . |
LOCRE0 | Loss of Clock Reset Enable 0 (0): Interrupt request is generated on a loss of OSC0 external reference clock. 1 (1): Generate a reset request on a loss of OSC0 external reference clock. |